69
30656E--
Technical documentation
Argus HSG
12.2.5 Service case: irregular running
behaviour
Fault
Cause
Remedy
Runs too fast/too slowly
Parameters not set correctly
Check parameters and re-enter them.
Motor faulty
Detach motor cable and push on again by hand.
Check whether motor is sluggish.
Shaft encoder faulty
Check shaft encoder LED on ETS 21. LEDs ash if the
door elements are pulled across the swing area.
Shock absorber faulty
Replace shock absorber.
12.2.6 Service case - unit does not move to
home position
Fault
Cause
Remedy
Control unit does not
recognise any home
position; unit only mo-
ves into home position
inexactly.
Shaft encoder faulty
Replace shaft encoder.
Shaft encoder incorrectly
installed
Replace shaft encoder. Zero index at a 45° angle to the
home position within the main swing area.
Reprogramme door position..
12.2.7 Service case - door leaf moves in the
wrong direction
Fault
Cause
Remedy
Door leaf continuously
presses against the
stopper.
Motor incorrectly polarised
Change motor phases.
Incorrect position parameters
Report.
Shaft encoder faulty
Check shaft encoder and replace if necessary.
12.2.8 Service case - permanent alarm
Fault
Cause
Remedy
Permanent alarm
CAN-Bus connection
Fault with master-slave
Check cabling.
Sensor faulty
Test sensor and replace if necessary.
Summary of Contents for Argus HSG-E02
Page 6: ...Technical documentation Argus HSG...
Page 12: ...12 Fig 1 1 5 1 30656E Technical documentation Argus HSG...
Page 13: ...13 Fig 1 1 5 2 30656E Technical documentation Argus HSG...
Page 14: ...14 Fig 1 1 5 3 30656E Technical documentation Argus HSG...
Page 18: ...18 30656E Technical documentation Argus HSG...
Page 44: ...44 30656E Technical documentation Argus HSG...
Page 50: ...50 30656E Technical documentation Argus HSG...
Page 54: ...54 30656E Technical documentation Argus HSG...
Page 62: ...62 30656E Technical documentation Argus HSG...