11.2.4 Check on running behaviour
Activity
Comment
Disconnect power to the unit.
Move the door leaf by hand.
Door leaf runs smoothly.
X
If the door does not run smoothly, it may be neces-
sary to change the drive.
11.2.5 Function test of locking mechanism
Activity
Comment
Block door elements in closed position.
Lock.
X
11.2.6 Function test of end-point cushioning
Activity
Comment
Trigger a single release in an incoming or outgoing
direction, and observe the movement of the door.
If the door swings back into the end-points, the
PID control must be adjusted.
Fig. 11.2.6-1
X
Software Flap Control Center (FCC)
Menu <Swing behaviour>