68
30656E--
Technical documentation
Argus HSG
12.2.1 Service case - door elements can be
moved freely
Fault
Cause
Remedy
The door element of
unit can be moved
freely
Motor cable is faulty
Control board faulty.
Inspect cable and plug
Replace control board (ETS 21cc).
12.2.2 Service case - unit blocked
Fault
Cause
Remedy
No release
Sensor dirty
Clean sensor.
Sensor faulty
Replace sensor.
Card reader faulty
Test the input to the control unit.
12.2.3 Service case - no release
Fault
Cause
Remedy
No release
Sensor faulty
Replace sensor.
No release signal
Check release signal.
Inspect sensor cable.
12.2.4 Service case - door element does not
open/close
Fault
Cause
Remedy
Door element does not
open/close.
Drive unit faulty
Replace drive unit.
No ready signal from the
control unit
Check control by ETS 21 (LED R1/R2).
Motor blocks/faulty
Inspection motor control (motor LED).
Power supply faulty
Check voltage (terminals 9, 11).
Door element does not
open.
No release signal
Check control by reader (LED I1/I2).
Summary of Contents for Argus HSG-E02
Page 6: ...Technical documentation Argus HSG...
Page 12: ...12 Fig 1 1 5 1 30656E Technical documentation Argus HSG...
Page 13: ...13 Fig 1 1 5 2 30656E Technical documentation Argus HSG...
Page 14: ...14 Fig 1 1 5 3 30656E Technical documentation Argus HSG...
Page 18: ...18 30656E Technical documentation Argus HSG...
Page 44: ...44 30656E Technical documentation Argus HSG...
Page 50: ...50 30656E Technical documentation Argus HSG...
Page 54: ...54 30656E Technical documentation Argus HSG...
Page 62: ...62 30656E Technical documentation Argus HSG...