59
Fig. 9.2.2-1
Fig. 9.2.2-2
30656E--
Technical documentation
Argus HSG
9.2.2 Unit
software
The software is imported onto every ETS 21.
The transfer takes place via an RS 232 interface,
with the aid of computer. The program MSK-Termi-
nal is required to download the unit software.
The latest unit software can be requested via the
customer service department.
Transfer unit software
Prerequisites:
Computer with transfer cable
(RS 232 interface)
Software for downloading the MSK-Terminal les
Control software for the processor Bootload-
er256.mhx is transferred.
Procedure for transfer
see
Fig. 9.2.2-2
Connect the PC to the control unit via the RS
232 interface.
Set the DIP switches 5 + 6 on the ETS 21 board
to OFF.
Call up the MSK-Terminal program for data
transfer.
On the top right of the screen, select the eld
<Erase Datasegment SA2> (place a tick).
Select the <Com> mode, <Settings>, and set
the interface (generally <Com 1>). Accept all the
other settings.
Select <Com> mode and click on <Open>. The
port address is shown in the status bar.
Click on the <Reset> button in the bottom left of
the screen. The status bar shows the connection
data and, for a short time, also the noti cation
<Status: CD changed>. If this noti cation does
not appear, check the connection between the
PC and ETS 21.
Press the reset button RST1 on the ETS 21
board.
•
•
•
Summary of Contents for Argus HSG-E02
Page 6: ...Technical documentation Argus HSG...
Page 12: ...12 Fig 1 1 5 1 30656E Technical documentation Argus HSG...
Page 13: ...13 Fig 1 1 5 2 30656E Technical documentation Argus HSG...
Page 14: ...14 Fig 1 1 5 3 30656E Technical documentation Argus HSG...
Page 18: ...18 30656E Technical documentation Argus HSG...
Page 44: ...44 30656E Technical documentation Argus HSG...
Page 50: ...50 30656E Technical documentation Argus HSG...
Page 54: ...54 30656E Technical documentation Argus HSG...
Page 62: ...62 30656E Technical documentation Argus HSG...