58
Fig. 9.2.1-1
Fig. 9.1.1-2
30656E--
Technical documentation
Argus HSG
one oating contact per direction of passage (at
KGB) or control of the card reader in line with the
system supplier’s speci cations
If the identi cation system required additional
feedback signals, further cables are required.
Mains supply line
The mains supply line must be laid in accord-
ance with the line lengths stipulated in the
national or regional connection regulations.
CAN-Bus (external)
Lay together in an empty conduit M 40
All control lines should be exibly designed.
9.2
Installation of software
9.2.1 Control software for the processor
bootloader
The MSK processor controls the functions on the
ETS21.
The basic software is saved in the le Bootloader.
mhx.
The transfer of the program from the basic soft-
ware, known as bootstrapping, takes place with the
program Fujitsu MCU Flash Programmer. The le
Bootloader.mhx is imported by the computer via an
internal RS 232 interface.
For the transfer, the DIP switches 5 and 6 on the
board are set to ON (bootstrapping).
With all control units supplied by KGB, the
Bootloader.mhx le has already been trans-
ferred.
Summary of Contents for Argus HSG-E02
Page 6: ...Technical documentation Argus HSG...
Page 12: ...12 Fig 1 1 5 1 30656E Technical documentation Argus HSG...
Page 13: ...13 Fig 1 1 5 2 30656E Technical documentation Argus HSG...
Page 14: ...14 Fig 1 1 5 3 30656E Technical documentation Argus HSG...
Page 18: ...18 30656E Technical documentation Argus HSG...
Page 44: ...44 30656E Technical documentation Argus HSG...
Page 50: ...50 30656E Technical documentation Argus HSG...
Page 54: ...54 30656E Technical documentation Argus HSG...
Page 62: ...62 30656E Technical documentation Argus HSG...