39
30656E--
Technical documentation
Argus HSG
Day mode
(door open in home position)
Function
Sensors
Signal
Door
Comment
S1
S2 S3
S4
Out-
side
Inside
Alarm
>
<
Red
Red
x
----
Alarm upon entering the unit
>
Green
Red
-- --
Door remains open.
<
Red
Red
x
----
Door closes.
>
Red
Red
x
----
Door closes.
<
Red
Green
-- --
Door remains open.
>
Green
Red
-- --
Door opens.
>
<
Red
Red
x
----
Door closes.
>
<
Red
Red
x
-- --
Door does not close (protective function).
> <
Green
Red
x
-- --
Door does not close (protective function).
> >
Red
Red
x
-- --
Door does not close (protective function).
> >
Red
Red
x
-- --
Door does not close (protective function).
> >
Red
Red
x
-- --
Door does not close (protective function).
>
>
Red
Red
x
-- --
Door does not close.
<
Red
Green
-- --
Door opens.
>
<
Red
Red
x
----
Door closes.
>
<
Red
Red
x
-- --
Door does not close (protective function).
> <
Red
Red
x
-- --
Door does not close (protective function).
< <
Red
Red
x
-- --
Door does not close (protective function).
< <
Red
Red
x
-- --
Door does not close (protective function).
<
<
Red
Red
x
-- --
Door does not close (protective function).
Summary of Contents for Argus HSG-E02
Page 6: ...Technical documentation Argus HSG...
Page 12: ...12 Fig 1 1 5 1 30656E Technical documentation Argus HSG...
Page 13: ...13 Fig 1 1 5 2 30656E Technical documentation Argus HSG...
Page 14: ...14 Fig 1 1 5 3 30656E Technical documentation Argus HSG...
Page 18: ...18 30656E Technical documentation Argus HSG...
Page 44: ...44 30656E Technical documentation Argus HSG...
Page 50: ...50 30656E Technical documentation Argus HSG...
Page 54: ...54 30656E Technical documentation Argus HSG...
Page 62: ...62 30656E Technical documentation Argus HSG...