Argus HSG
2.3 Technical
dangers
Technical dangers are principally of relevance
for specialist personnel. They arise during
maintenance and servicing.
DANGER
Risk of injury from electric current
A voltage of 230 V AC is required to operate
the unit.
The connection must be carried out cor-
rectly and in accordance with the relevant
applicable regulations.
Should incidents occur which are not listed in
these instructions, the manufacturer must be
noti ed of these without delay.
It is vital that the accident prevention regula-
tions and the recognised technical safety in-
structions, see e.g. DIN 18650, are followed.
2.4
Qualification of service
personnel
DANGER
Risk of injury with incompetent mainte-
nance and service personnel
Units that have been incorrectly set can lead
to injuries , e.g. impacts or squashing.
Personnel must have the necessary unit-
speci c knowledge to install and maintain
the unit (see
Section 2.4.1 Safety instruc-
tions for automatic door systems
).
Repairs and maintenance may only be
carried out be personnel who are familiar
with the relevant safety instructions for
automatic door systems and hold authori-
sation from KGB (see
Section 2.4.2 Unit-
speci c knowledge
).
2.4.1 Safety instructions for automatic
door systems
De nition: Expert
Someone is an expert if he/she has acquired
the required knowledge concerning the safe
operation:
of automatic door systems as a result of
his/her professional training and experi-
ence and
continuously refreshes or updates this
knowledge in accordance with the current
state-of-the-art.
Technical experts have to conduct an objec-
tive evaluation regarding the operational
safety of door systems.
Expert inspection as part of a course
An expert inspection must take place in accordance
with the FTA (Fachverband Türautomation - Asso-
cation for Door Automation) guidelines, Part B, see
Section 2.5 Expert inspection and inspection book
Location/provider of the expert inspection
The course can be followed with KGB or another
provider recognised by the FTA.
2.4.2 Unit-specific
knowledge
KGB offers appropriate courses in Bühl.
KGB will also carry out course at other sites on
request.
2.5 Expert inspection and
inspection book
2.5.1 Time and frequency of the expert
inspection
For systems that are subject to BGR 232 and DIN
18650, an expert inspection must be carried out
every year.
The rst inspection takes place as part of com-
missioning (= initial inspection, see
Section
2.5.1.1 Carrying out the initial inspection
).
•
•
•
Summary of Contents for Argus HSG-E02
Page 6: ...Technical documentation Argus HSG...
Page 12: ...12 Fig 1 1 5 1 30656E Technical documentation Argus HSG...
Page 13: ...13 Fig 1 1 5 2 30656E Technical documentation Argus HSG...
Page 14: ...14 Fig 1 1 5 3 30656E Technical documentation Argus HSG...
Page 18: ...18 30656E Technical documentation Argus HSG...
Page 44: ...44 30656E Technical documentation Argus HSG...
Page 50: ...50 30656E Technical documentation Argus HSG...
Page 54: ...54 30656E Technical documentation Argus HSG...
Page 62: ...62 30656E Technical documentation Argus HSG...