Then setup the desired homing type in
S-0-0147
Homing parameter
. Please see available
options in the table below.
Supported options of
S-0-0147
– Homing Parameter.
(1)
If
using
MAC
motors
with
absolute
multiturn
encoder
and
MIS/MILxxx
motors
which
do
not
have
an
in
‐
dex
pulse,
then
this
bit
is
don’t
care.
8.4.6
Real time bits.
Real time bits are supported as producer (from motor to master) in the MAC00-ES4x
module when mounted in a MAC400-MAC4500 motor. The MIS/MIL motors and the
other MAC motors do not support real time bits.
Used IDN’s with Real Time Bits:
“RO”=Read
Only,
”RW”=Read
and
Writeable,
”C”
=
Map
able
to
Cyclic
data,
“T”
=
Map
able
to
real
Time
bits.
(3)
Only
available
in
MAC400
‐
MAC4500
with
MAC00
‐
ES4x.
Bit
Description
Comments
Supported
15-11 Reserved
-
-
10
Homing with Positive Stop
(Torque homing)
0 = Without hard stop.
1 = With hard stop (hard stop is used, instead of home
switch. Set torque in
S-0-0530
(
Clamping torque
)
Yes
9
Homing with Limit switch
Always 0. Limit switch is not used.
No
8
Drive controlled homing
with homing distance
Always 0. Homing distance is not selected
No
7
Position after drive con-
trolled homing
Always 1. Drive is positioned at the reference position
(
S-0-0052
)
No
6
Evaluation of position
feedback marker pulse
(index pulse)
0 = The index pulse is evaluated.
1 = The index pulse is not evaluated.
Yes
(1)
5
Evaluation of home switch
Always 0. Home switch is evaluated, but if bit 10 is set
then it is not evaluated.
Partly
4
Interpretation in the drive
Always 0. Home switch and homing enable are used
No
3
Homing feedback
Always 0. Motor feedback is used for homing and not
the external feedback
No
2
Home switch
Always 1. Home switch is connected to drive
No
1
Position feedback marker
pulse (index pulse)
0 = First index pulse after the positive edge of the home
switch.
1 = First index pulse after the negative edge of the
home switch.
Yes
0
Homing direction
0 = Positive; motor shaft turns clockwise
1 = Negative; motor shaft turns counter-clock wise
Yes
IDN
Description
Default
Unit
Attributes
S-0-0398
(3)
IDN list of configurable real-time bits as producer
S-0-0401,
S-0-0402,
S-0-0409 -
S-0-0412
IDN
RO
S-0-0399
(3)
IDN list of configurable real-time bits as consumer 0-0-0000
IDN
RO
S-0-1050.0.20
(3)
IDN allocation of real time bit
0
-
RW
S-0-1050.0.21
(3)
Bit allocation of real time bit
0
-
RW
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...