![JVL MAC00-EC4 User Manual Download Page 174](http://html.mh-extra.com/html/jvl/mac00-ec4/mac00-ec4_user-manual_2036628174.webp)
174
JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
Now set the motor into position mode and thereby activate the motor.
Ex.
The motor needs to be activated by setting it into position mode so we need to set the
mode register to the value 2. Mode = 2 which is position mode, now the motor will use the
acceleration and the velocity just configured.
(Modbus address 4-5 = register 2).
Set a position in the motor by writing a position to register 3 (P_SOLL = Modbus address 6-7),
in the example shown below is used position 5,000,000 (= 0x 004C 4B40), remark the order.
TT3068-01GB
TT3069-01GB
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...