JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
211
8.4.4
Probes
Probes are the capture functionality of Sercos
®
, which is only available with MAC400-
MAC4500 motors.
Used IDN’s in probes:
“RO”=Read
Only,
”RW”=Read
and
Writeable,
”C”
=
Map
able
to
Cyclic
data,
“T”
=
Map
able
to
real
Time
bits.
(3)
Only
available
in
MAC400
‐
MAC4500
with
MAC00
‐
ES4x.
The MAC00-ES4x JVL Sercos
®
module supports position capture when installed in a
MAC400-MAC4500 motor. Here the AIN1 and AIN2 inputs act as the triggers for probe
1 and probe 2, when a programmed analog level is reached (d5V).
Remark!
Probe 2 is only available when using the extended I/O module – MAC00-ES41.
The IDN
S-0-0169
is used for setting up the probe functionality. Only single measuring
is supported, meaning for every capture the probe has to be re-enabled. Enable a specific
edge of probe/capture is done by setting one of the bits 0-3 in IDN
S-0-0169
as seen in
the below table.
The JVL Sercos
®
implementation supports the following bits/features of IDN
S-0-0169
probe control:
IDN
Description
Default
Unit
Attributes
S-0-0130
(3)
Probe value 1 positive edge
-
-
RO, C
S-0-0131
(3)
Probe value 1 negative edge
-
-
RO, C
S-0-0132
(3)
Probe value 2 positive edge
-
-
RO, C
S-0-0133
(3)
Probe value 2 negative edge
-
-
RO, C
S-0-0169
(3)
Probe control
0
-
RW
S-0-0401
(3)
Probe 1
-
-
RO, C, T
S-0-0402
(3)
Probe 2
-
-
RO, C, T
S-0-0405
(3)
Probe 1 enable
0
-
RW
S-0-0406
(3)
Probe 2 enable
0
-
RW
S-0-0409
(3)
Probe 1 positive latched
-
-
RO, C, T
S-0-0410
(3)
Probe 2 negative latched
-
-
RO, C, T
S-0-0411
(3)
Probe 1 positive latched
-
-
RO, C, T
S-0-0412
(3)
Probe 2 negative latched
-
-
RO, C, T
S-0-0426
(3)
Measuring data allocation 1 (Probe 1 signal selection)
S-0-0051
IDN
RW
S-0-0427
(3)
Measuring data allocation 2 (Probe 2 signal selection)
S-0-0051
IDN
RW
S-0-0428
(3)
IDN list of configurable measuring data
S-0-0051
IDN
RO
Bit
Description
Comments
Supported
15-9
Reserved
-
-
8
Activation
Probes are always activated when switching from
PL to OL regardless of the state of this bit
No
7
Reserved
-
-
6
Probe 2 continuous measuring Shall be zero – Only single measuring supported.
No
5
Probe 1 continuous measuring Shall be zero – Only single measuring supported.
No
4
Reserved
-
-
3
Probe 2 negative edge
1 = Negative edge active
Yes
2
Probe 2 positive edge
1 = Positive edge active
Yes
1
Probe 1 negative edge
1 = Negative edge active
Yes
0
Probe 1 positive edge
1 = Positive edge active
Yes
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...