Please note that you should always use a home offset (object 0x607C) when using torque
homing. This is to ensure that the motor moves away from the end limit. The sign of the
home offset should be the opposite of the homing direction. For example, when using a
negative homing direction, the home offset could be 5000.
Cyclic Synchron Position mode (csp)
This mode is used when synchronization between several drives are needed in position
mode. The default PDO addresses this mode. It is the preferred mode for the NC sys-
tem in TwinCAT. When using CSP mode it is highly recommneded to use Distributed
Clock, in order not to loose any cyclic frames.
If wanting to enable this mode as startup mode in TwinCAT then follow the
steps
below:
WARNING
: The CSP mode is NOT recommended for MAC050-141, as these
motors do not support Distributed Clock, and have a minimum cycle time of
16ms when using DSP-402.
Step 1-3.
Select the drive and press the “Startup” tab, then press the “New” button, as shown in
the below picture.
!
TT3094-01GB
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...