Use only the table below for
firmware build numbers above 1400
. If using an Ethernet firmware
with a lower build number then refer to the table on the next page.
MIS/MIL motor commands - Only applicable for MIS/MIL motors
Command no.
Command description
Motor
only
FastMac
commands
(via
module
cmd
register)
Hex
Dec
0x0100 0060
16777312 No operation
0x0100 0061
16777313 Reset errors and warnings
0x0100 0062
16777314 P_SOLL = 0
0x0100 0063
16777315 P_IST = 0
0x0100 0064
16777316 Reserved ( do not use)
0x0100 0065
16777317 V_SOLL = 0
0x0100 0066
16777318 Reserved ( do not use)
0x0100 0067
16777319 Reset InPos, Acc, Dec
0x0100 0068
16777320 Reserved ( do not use)
0x0100 0069
16777321 Reserved ( do not use)
0x0100 006A
16777322 Reserved ( do not use)
0x0100 006B
16777323 Reserved ( do not use)
0x0100 006C
16777324 Activate P1, V1, A1, T1
0x0100 006D
16777325 Activate P2, V2, A2, T2
0x0100 006E
16777326 Activate P3, V3, A3, T3
0x0100 006F
16777327 Activate P4, V4, A4, T4
0x0100 0070
16777328 Start zero search
0x0100 0071
16777329 P_SOLL = P_IST + P7
0x0100 0072
16777330 P_SOLL = P_IST + P8
0x0100 0073
16777331 No operation
0x0100 0074
16777332 Select absolute position mode
0x0100 0075
16777333 Select relative position mode
0x0100 0076
16777334 Reserved, do not use
0x0100 0077
16777335 Copy P_NEW to both P_SOLL and P_IST
0x0100 0078
16777336 Add P_NEW to both P_SOLL and P_IST
0x0100 0079
16777337 Reserved ( do not use)
0x0100 007A
16777338 Reserved ( do not use)
0x0100 007B
16777339 Reserved ( do not use)
0x0100 007C
16777340 Reserved ( do not use)
0x0100 007D
16777341 Reserved ( do not use)
0x0100 007E
16777342 Reserved ( do not use)
0x0100 007F
16777343 Reserved ( do not use)
Motor
only
normal
commands
(via
module
cmd
register)
0x0100 0101
16777473 Re-sync P_IST and P_ENCODER position
0x0100 010B
16777483 Reset motor
(not recommended, use synchronized version instead)
.
0x0100 010C
16777484 Save motor parameters in flash and reset motor
(not recommended, use synchronized ver-
sion instead)
.
0x0100 010D
16777485 Save to flash memory, then continue normal execution.
NOTE: Some registers used only during startup!
0x0100 0171
16777585 Turn on LED flashing
0x0100 0172
16777586 Turn off LED flashing
Only MIS/MIL
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...