![JVL MAC00-EC4 User Manual Download Page 234](http://html.mh-extra.com/html/jvl/mac00-ec4/mac00-ec4_user-manual_2036628234.webp)
234
JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
Use only the table below for
firmware build numbers lower than 1400
. If using an Ethernet module
firmware with a higher build number then refer to the table on the previous page.
Table continued next page
Command no.
Command description
Hex
Dec
MAC050 - MAC141
MAC400 – MAC4500
0x 8000 0001
2147483649
Reset motor
(not recommended, use synchronized
version instead)
.
< Same as
0x 8000 0002
2147483650
Save motor parameters in flash and reset motor
(not
recommended, use synchronized version instead)
.
< Same as
0x8000 00E0
2147483872 No operation
< Same as
0x8000 00E1
2147483873 Reset error
(Clear error bits in motor register 35)
< Same as
0x8000 00E2
2147483874 P_SOLL = 0
< Same as
0x8000 00E3
2147483875 P_IST = 0
< Same as
0x8000 00E4
2147483876 P_FNC = 0
< Same as
0x8000 00E5
2147483877 V_SOLL = 0
< Same as
0x8000 00E6
2147483878 T_SOLL = 0
< Same as
0x8000 00E7
2147483879 Reset IN_POS, AC C,DEC
< Same as
0x8000 00E8
2147483880 P_FNC = (FLWERR - P7) * 16
< Same as
0x8000 00E9
2147483881 P_FNC = (FLWERR - P8) * 16
< Same as
0x8000 00EA
2147483882 Reserved
< Same as
0x8000 00EB
2147483883 Reserved
< Same as
0x8000 00EC
2147483884 Activate P1,V1,A1,T1,L1,Z1
< Same as
0x8000 00ED
2147483885 Activate P2,V2,A2,T2,L2,Z2
< Same as
0x8000 00EE
2147483886 Activate P3,V3,A3,T3,L3,Z3
< Same as
0x8000 00EF
2147483887 Activate P4,V4,A4,T4,L4,Z4
< Same as
0x8000 00F0
2147483888 Start search zero
< Same as
0x8000 00F1
2147483889 P_SOLL = P_IST + P7;
P_SOLL = P_IST + P7 – FLWERR;
0x8000 00F2
2147483890 P_SOLL = P_IST + P8;
P_SOLL = P_IST + P8 – FLWERR;
0x8000 00F3
2147483891 Reserved
< Same as
0x8000 00F4
2147483892 Select absolute position mode
< Same as
0x8000 00F5
2147483893 Select relative position mode using P_SOLL
< Same as
0x8000 00F6
2147483894 Select relative position mode using P_FNC
< Same as
0x8000 00F7
2147483895
Synchronize position manually using
absolute new values.
P_IST = P_NEW;
P_SOLL = P_NEW;
P_FUNC = P_NEW * 16;
Synchronize position manually using
absolute new values.
P_IST = P_NEW;
P_SOLL = P_NEW;
P_FNC = (P_NEW + FLWERR)*16;
0x8000 00F8
2147483896
Synchronize position manually using relative
new values. (basically offset the position
range with the value of P_NEW).
P_IST = P_IST + P_NEW;
P_SOLL = P_NEW;
P_FUNC = (P_NEW * 16);
< Same as
0x8000 00F9
2147483897 No operation
< Same as
0x8000 00FA
2147483898 No operation
< Same as
0x8000 00FB
2147483899 No operation
< Same as
0x8000 00FC
2147483900 No operation
< Same as
0x8000 00FD
2147483901 Reserved
< Same as
0x8000 00FE
2147483902 Reserved
< Same as
0x8000 00FF
2147483903 Reserved
< Same as
Only MAC
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...