03.13 EN
78
4.4
Starting procedure for the TFG
DANGER!
Risk of escaping liquid gas if the truck does not start
X
Note the safety regulations governing the handling of liquid gas
(see "Safety regulations for handling diesel fuel and LPG" on page 41)
X
Close the gas bottle shut-off valve.
X
Set the key switch to "O"
X
Notify your superior.
Procedure
• Slowly open the shut-off valve on the
LPG bottle, see "LPG bottles" on
page 47.
• Insert the key in the key switch (81). Set
key switch to “I”.
•
• All the indicators light up briefly as a
function check and the (102) display is
activated.
Z
All the indicators except for the engine
oil pressure display (88), parking brake
(89), truck operation indicator (102) and
charge current indicator (93) should go
out after a short while. If not, stop the
start-up process and rectify the fault.
• Using the key, set the key switch (81) to
“II” to apply the starter.
Z
Only apply the starter continuously for a
maximum of 15 seconds.
The truck is equipped with an
immobiliser which prevents it from
starting again while the engine is
running.
• Release the key as soon as the engine starts. The key switch automatically reverts
to the "I" position.
Z
All indicators except for the parking brake (89) and the truck operational indicator
(102) should go out as soon as the engine starts. If not, switch off the engine
immediately and rectify the fault.
• Test the brake pedal and parking brake button (105).
Truck is operational.
0
I
II
81
km/h
R
73
92
88
93
89 97
102
105
Summary of Contents for DFG 425s
Page 1: ...DFG TFG 425s 435s G 10 07 Operating Instructions 51077936 51209061 01 09 03 13 ...
Page 3: ......
Page 5: ...03 13 EN 4 ...
Page 15: ...03 13 EN 14 ...
Page 24: ...23 03 13 EN ...
Page 41: ...03 13 EN 40 ...
Page 46: ...45 03 13 EN Fuelling is now complete ...
Page 53: ...03 13 EN 52 ...
Page 192: ...191 03 13 EN t Series equipment o Optional equipment ...