03.13 EN
152
7.2.4 Starting aid
WARNING!
Danger from overheating
X
Use only an ISO 6722 battery jump lead
with fully insulated terminal pliers and a
lead diameter of at least 25 mm
2
.
Z
The jump start connection (199) is located in
the main fuse box on the starter battery.
Procedure
• Open the engine cover, see "Opening the
engine cover" on page 166.
• Attach the red lead of the donor battery to the
jump start connection (199).
• Attach the black lead to the negative terminal
of the donor battery and the mass point of the
crane eye to the engine.
• Switch on the ignition by turning the key in the key switch (81) to the "I" position.
• Press the override switch (213).
• Start the engine by turning the key in the key switch (81) to the "I" position.
• When the engine has started first remove the negative lead followed by the positive
lead.
Z
If the starter motor does not switch on the motor after connecting the battery
terminals, check that the battery leads are positioned correctly.