77
Models
Revision 03-2012
Toucan 1210
Toucan 1310
4.6.2 Fuses
Power circuit fuse
Never replace a faulty protection device by
another one of different characteristics.
L
OCATION
:
Forked fuse 325A type C20
ELECTRICAL SYSTEM
4
4
4.6 Circuit breakers - Fuses
4.6.1 Circuit breakers
Panel mounted circuit breakers 5-7A
(depending on models)
F
UNCTION
: General protection of the control circuit.
L
OCATION
: Face of the emergency control panel (Lower
control box).
Circuit breakers on electronic card
L
OCATION
: Emergency control panel electronic card
(inside the box).
1- Circuit breaker 3,15A
F
UNCTION
: Protection of the centralized filling pump
circuit (push to reset).
2- Circuit breaker 0,63A
F
UNCTION
: Protection of the battery discharge indicator
circuit (push to reset).
! CAUTION
Disconnected
position
N o r m a l
position