75
Models
Revision 03-2012
Toucan 1210
Toucan 1310
ELECTRICAL SYSTEM
4
4
Description and values of parameters for models
Toucan 1210 and Toucan 1310.
Calibrator use as measuring instrument :
BATT V :
The measure of battery voltage can be done at any time,
even when the work platform is in operation, thus
enabling analysis, if necessary, of the battery voltage
fluctuations.
MOTOR V :
The measure of the motor voltage in operation enables
the determination, for a chosen speed, of the voltage to
be applied at the motor terminals. The value of this
voltage calculated in percentage of the battery voltage
determines the speed setting.
MOTOR AMP. :
The measure of the current at the motor enables the
determination of the current limit value to which the
controller must be set when the machine is driven on a
ramp.
TEMP °C :
The measure of the temperature enables the analysis of
the controller temperature increases, therefore the
operating conditions of the work platform.
Parameter
Description
Unit Pitch
Values
Toucan 1210 / 1310
Observations
Speed 1
Speed n°1 (variable)
%
1%
30%
Mast lowering movement.
Make up flow to the wheel motors.
Platform inclination movements.
Platform rotation movement.
Speed 2
Speed n°2 (variable)
%
1%
40%
Slewing movement.
38%
Low speed drive - motors displacement 332 cc/rev.
40%
Low speed drive - motors displacement 398 cc/rev.
43%
Low speed drive - motors displacement 500 cc/rev.
Speed 4
Speed n°4 (variable)
%
1%
80%
Jib elevation movement (tilt - stability control).
Mast elevation movement (tilt - stability control).
Speed 5
Speed n°5 (variable)
%
1%
100%
Jib elevation movement.
Jib lowering movement.
Mast elevation movement.
Telescope retraction / extension movements.
Speed 6
Speed n°6 (variable)
%
1%
100%
High speed drive
Speed 7
Speed n°7 (fixed)
%
1%
45%
Steering movement (joystick in neutral position).
Speed 3
Speed n°3 (variable)
%
1%