35
Models
Revision 03-2012
Toucan 1210
Toucan 1310
!
CAUTION
!
CAUTION
!
CAUTION
Repeated use of the brakes as emergency
brakes (action on the emergency stop during
a drive movement) will reduce the braking
torque. The brakes must be tested for
efficiency after emergency braking.
NOTE
Before starting a motor, the housing must be
filled with hydraulic oil through Port "2".
NOTE
Disassembly of the wheel motors requires
specific competences and tooling. Contact
JLG Product Support.
HYDRAULIC SYSTEM
3
3
!
CAUTION
Cyl. B Cyl. A
X
A1
A2
R
2
Ports identification :
Port A1
:
Supply port corresponding to the preferential rotation direction (Cyl. A).
Port A2
:
Supply port corresponding to the preferential rotation direction (Cyl. B).
Port R
:
Return port corresponding to the preferential rotation direction.
Port X
:
Brake pilot port.
Port 2
:
Housing drain port.
The brake pilot pressure should not exceed
3,0 MPa (30 bar) continuous.
The pressure in the motor housing should not
exceed 0,1 MPa (1 bar) after the stabilisation
of hydraulic fluid temperature (0,3 MPa (3
bar) max. when cold).
Do not operate the motors without any load
and at maximum speed.