109
Models
Revision 03-2012
Toucan 1210
Toucan 1310
BATTERY - CHARGER
5
5
Troubleshooting
The flashing LED and an intermittent acoustic signal indicate an alarm. In case of alarm, the charger stops
supply current.
CONDITION OF THE
FLASHING LED
ALARM TYPE
DESCRIPTION (Action)
RED
Battery presence
- Battery not connected to the charger (disconnect the charger
and check battery connection)
- Battery too discharged (disconnect the charger and let the
battery stand half a day before resuming the charge procedure.
If the problem persists contact JLG.
YELLOW
Temporisation
- The charge phase 1 and/or 2 have a duration exceeding the
maximum allowed (check the voltage of each battery cell.
Contact JLG Product Support).
RED / YELLOW
Battery current
- Loss of output current control (fault on the control logic :
Contact JLG Product Support).
RED / GREEN
Battery voltage
- Loss of output voltage control (check the battery connections.
Fault of the control logic : Contact JLG Product Support).
RED /
YELLOW /
GREEN
Thermal safety
Overheating of the semi conductors (check the fan's
operation).