Models
Revision 03-2012
120
Toucan 1210
Toucan 1310
SERVICE - MAINTENANCE
7
7
7.9 Hydraulic power unit
The brushes (Qty 4) of the hydraulic power unit
motor(s) must be checked regularly. The ventilation
holes of the motor(s) must be cleaned regularly with
compressed air as indicated below :
Brush removal :
1- Disconnect the battery plug.
2- Remove the protection covers.
3- Remove the brushes attachment screws.
4- Lift the spiral springs and remove the brushes
from their housing.
All 4 brushes must be replaced if their length
is below 10 mm.
During removal / assembly, do not
interchange the brushes.
Brush installation :
1- Lift the spiral spring and install the brush.
2 Install the brush fixation screws.
3- Install the protection covers.
!
CAUTION
7.10 Battery
7.10.1 Maintenance of the centralised
filling system
It is necessary to service the centralised filling system
once a year. Cleaning intervals must be shortened in
case of premature clogging of the filter or reduction in
the water flow.
- Disconnect and clean the filter by reversing the
water flow.
- Check the hose for flexibility. In case of
hardening in the connection area, replace the
hose.
- Check all the fittings are tight and do not leak.
- Check the caps individually. Ensure of the perfect
mobility of the floats. In case of excessive
clogging, replace the cap. It is recommended to
replace the caps every 2 or 3 years.
7.10.2 Cleaning - Battery maintenance
It is necessary to clean the battery regularly to prevent
salt formation and current arcing that could damage the
machine.
- Clean the battery with a damp cloth.
- Allow to dry and wipe the battery top with a
non fluffy cloth.
- Ensure the connections are clean and
tightened correctly.
NOTE
Coat the terminals and connections with a
grease or anti corrosion compound.
- Keep metallic containers clean. In case of
corrosion, clean, neutralise the corrosion and
apply anti-acid paint on the affected area.
- Drain the water that can accumulate at the
bottom of the container (electrolyte overflow,
leak of the centralised filling system, battery
cleaning...).
Filter
ç
10
mm
mi
ni
Areas to blow
air through
Cover
Spring
Brush