107
Models
Revision 03-2012
Toucan 1210
Toucan 1310
BATTERY - CHARGER
5
5
5.2 Chargers
5.2.1 High frequency charger "Zivan
NG3"
Supply
Protections
Prior to any operation requiring charger
cover removal, the charger must be
disconnected from the battery and from the
AC source. Failure to do so could result in
death or serious injury to personnel.
Auxilliary contacts
Technical features : changeovers contacts
0,3 A
: 125 VAC
0,3 A
: 110 VDC
1 A
: 30 VDC
Connector : Faston 6,3 x 0,8 mm.
AUX1
NC
C
NO
AUX2
NC
C
NO
AUX2
AUX1
Supply voltage
Frequency
Absorbed current
F7 BTTR
17 V eff.
F7 BSTR
15 V eff.
Absorbed maximum current
(P = P max.)
Absorbed maximum power
(P = P max.)
50 / 60 Hz
3 kW
20 A eff.
230 ± 10% V eff.
Input fuse
Output fuse
Photo with cover open
DANGER
SECTION
FUNCTION
DESCRIPTION
AUX 1
Main presence
When the equipment is switched on, the
contact Normally Open (NO) CLOSES and
instead the contact Normally Closed (NC)
OPENS.
AUX 2
End of charge or
Trickle Phase
When the Stop Phase or the No Stop
Phase is reached, the contact Normally
Open (NO) CLOSES and instead the
contact Normally Closed (NC) OPENS.
Input fuse F1
Inside the equipment
20 A
Output fuse F2
Inside the equipment
125 A
Minimum output voltage of operation
(Battery detector)
Equipment turn on
1,5 V/cell.
Reversal of output polarities
At the connection to
the battery
Protection
provided
by fuse F2
Thermal protection of semi
conductors
(Temperature of thermal alarm)
TA = 55°C
100°C