3
3.12 Check valves manifold ("power plus" option)
DV2
: Solenoid valve (NO).
1a
: Check valve
1b
: Check valve
2
: Pressure switch
F
UNCTION
: Combines the flow from both pumps when the "power plus" option is installed.
Manifold schematic
DV2 : Solenoid valve (NO).
Check valve (1a)
F
UNCTION
: Prevents the return of the oil flow supplied by the main hydraulic power unit through the pump of the
auxilliary power unit.
Check valve(1b)
F
UNCTION
: Prevents the return of the oil flow supplied by the auxilliary hydraulic power unit through the pump of
the main power unit.
PORT GP :
auxilliary pump inlet
PORT PP :
Main pump inlet
Torque value : 30 N.m maxi
F
UNCTION
: Dumping of the oil flow supplied by the
secondary hydraulic power unit.