65
Models
Revision 03-2012
Toucan 1210
Toucan 1310
ELECTRICAL SYSTEM
4
4
5. Measure and record voltage U1 in millivolts
at the sensor's white () and yellow
(signal -) terminals.
6. Lower the machine, telescope retracted,
structure at 90°, work platform empty.
7. Install the sensor on the structure as indicated
below. Install the screws using Loctite
®
243.
Torque the screws to 60 Nm.
8. Install the charger protection cover.
9. Return the structure in line with the chassis,
measure and record the voltage U2 in millivolts
at the sensor's white () and yellow
(signal -) terminals. The voltage U2 must be
within ± 4 millivolts of the value of voltage U1
recorded previously.
10. Wait for 45 mn (time for the Loctite to set) before
adjusting the threshhold for alarm set off.
NOTE
The alarm may be triggered during the
installation of the sensor (the system is not
adjusted yet) : switch the machine off once
the voltages U1 and U2 have been recorded.
Adjustment of threshhold for setting off
Do not cut the power off from the electronic
card during the adjustment phase to prevent
loss of data.
1. Read this procedure completely before applying
it.
2. Position the machine on flat and horizontal
ground. Fully lower the machine, telescope
retracted, superstructure in line, work platform
empty.
3. Switch the machine off and install the jumper
J14. Plug the serial cable RS-232 on the J12
connector.
4. Switch the machine on (select the ground
control panel).
ç
the green led [D3] comes on
ç
the red led [D20] may come on.
5. Start the adjustment phase : depress the SW1
button.
ç
the yellow [D21] and red [D20] led light up.
6. Determine the "zero" of the system: Depress
the SW2 button.
ç
the red led [D20] is more luminous when
the SW2 button is depressed.
The platform must be in the same position
as described in step 2.
7. Place a 200 kg load evenly distributed on the
work platform floor.
8. Perform the following cycle twice using the
ground control panel:
- Raise the jib to the horizontal.
- Fully extend the telescope.
- Fully raise the mast.
- Retract the telescope.
- Lower the mast.
- Lower the jib.
9. Position the machine in the following
configuration:
- Jib horizontal.
- Telescope fully extended.
- Mast fully raised.
! CAUTION
! CAUTION