4-120
4222983 Second Edition
ELECTRICAL
4
DTC: Generator Fault 56
Generator temperature greater than 340° F (171° C).
DTC: Generator Fault 57
Generator temperature less than -20° F (-29° C).
DTC: Generator Fault 58
Rectifier temperature greater than 340° F (171° C).
Probable Cause
Remedy
Running on high load (150A continuous).
Remove load.
Debris on or around genset fan.
Remove debris and clean the genset fan.
Faulty connections.
Check steering motor connections; make sure connections are dry, clean of corrosion
and tight.
Faulty wiring harness.
Make sure wiring harness is free of nicks and cuts and not pinched to machine frame.
Faulty fan relay.
Test relay. (See “Fan Relay Test” on page 4-128.)
Faulty genset fan.
Substitute the genset fan with a known good genset fan. If system now works, re-install
old component to verify fault returns.
Faulty generator control unit.
Substitute the generator control unit with a known good generator control unit. If system
now works, re-install old component to verify fault returns.
Faulty permanent magnet generator
temperature sensor.
Replace generator. If system now works, re-install old component to verify fault returns.
Probable Cause
Remedy
Faulty connections.
Check steering motor connections; make sure connections are dry, clean of corrosion
and tight.
Faulty wiring harness.
Make sure wiring harness is free of nicks and cuts and not pinched to machine frame.
Faulty generator control unit.
Substitute the generator control unit with a known good generator control unit. If system
now works, re-install old component to verify fault returns.
Probable Cause
Remedy
Running on high load (150A continuous).
Remove load.
Debris on or around genset fan.
Remove debris and clean the genset fan.
Faulty connections.
Check steering motor connections; make sure connections are dry, clean of corrosion
and tight.
Faulty wiring harness.
Make sure wiring harness is free of nicks and cuts and not pinched to machine frame.
Faulty fan relay.
Test relay. (See “Fan Relay Test” on page 4-128.)
Faulty genset fan.
Substitute the genset fan with a known good genset fan. If system now works, re-install
old component to verify fault returns.
Faulty generator control unit.
Substitute the generator control unit with a known good generator control unit. If system
now works, re-install old component to verify fault returns.
Faulty rectifier temperature sensor circuit.
Replace rectifier wiring. If system now works, re-install old component to verify fault
returns.
Summary of Contents for Eclipse 322
Page 1: ...Eclipse 322 Riding Greens Mower Technical Repair Manual 62801 62803 62805 Second Edition...
Page 2: ......
Page 4: ......
Page 8: ......
Page 13: ...SAFETY 4222983 Second Edition 1 5 1 9 41 8 1 8 64 8 4127335 10 4181865 11...
Page 20: ...1 12 4222983 Second Edition SAFETY 1 Page Intentionally Blank...
Page 110: ...4 36 4222983 Second Edition ELECTRICAL 4 Page Intentionally Blank...
Page 128: ...4 54 4222983 Second Edition ELECTRICAL 4 Page Intentionally Blank...
Page 241: ...ELECTRICAL 4222983 Second Edition 4 167 4 Page Intentionally Blank...
Page 242: ...4 168 4222983 Second Edition ELECTRICAL 4...
Page 266: ...5 24 4222983 Second Edition CHASSIS 5 Page Intentionally Blank...
Page 332: ...IX 14 4222983 First Edition INDEX IX...
Page 333: ......
Page 335: ......
Page 336: ......