Group 28: Operating hours meter
28-0
Missing operating hours meter
Please contact the Technical Support team.
28-1
Operating hours meter:
write error
28-2
Operating hours meter
corrected
Acknowledge the error.
If the error recurs, contact the Technical Support team.
28-3
Operating hours meter
converted
Group 29: SD card
29-0
No SD card
The option "Transfer the parameter file after Reset and Power on" is active, but
an SD card has not been inserted. Insert an SD card.
29-1
SD card: initialisation error
Unsuitable SD card?
Card write protection activated?
BOOT DIP switch activated (firmware download)?
Please contact the Technical Support team.
29-2
SD card: parameter set error
29-3
SD card: write error
29-4
SD card: firmware download
error
Group 30: Internal calculations
30-0
Internal calculation error
Please contact the Technical Support team.
Group 31: I²t
31-0
I²t motor
Is the motor blocked? Check the power rating of the drive
31-1
I²t servo drive
Check the power rating of the drive package.
31-2
I²t-PFC
Check the power rating of the drive package. Select operation without PFC.
31-3
I²t braking resistor
Braking resistor overloaded. Use external braking resistor.
31-4
I²t active power overload
Check the power rating of the drive package.
Group 32: PFC
32-0
DC bus circuit charging time
exceeded
Bridge for the internal braking resistor installed?Check the connection of the
external braking resistor.Please contact the Technical Support team.
32-1
Undervoltage for active PFC Check whether the power supply complies with the nominal data.
32-5
Brake chopper overload.
DC bus circuit could not be
discharged
Check the power on/off cycles of the power supply.