item Controller BL 1-04 /C
― Product manual
90
Group 40: SW limit switches
40-0
Negative SW limit switch
reached
Check the permissible positioning range.
40-1
Positive SW limit switch
reached
40-2
Target position beyond the
negative SW limit switch
The start of a positioning run has been suppressed, since the target is located
beyond the respective software limit switch.
Check the target position.
Check the positioning range.
40-3
Target position beyond the
positive SW limit switch
Group 41: Course program
41-0
Course program: synchroni
-
sation error
Flying saw: Check the parameterisation of the lead distance.
Group 42: Positioning
42-0
Positioning: no follow-up
position: stop
The positioning target cannot be reached with the current options.
Check the parameterisation of the position sets.
42-1
Positioning: reversal of rota
-
tion not permissible: stop
42-2
Positioning: reversal of
rotation after stop not
permissible
42-3
Positioning start rejected:
wrong operation mode
The change of the mode of operation could not be performed by way of the
position set.
42-4
Homing run required
Reset the option "Homing run required". Perform a homing run.
42-5
Rotary axis: rotating direc
-
tion not permissible
The calculated direction of rotation of the rotary axis is not permissible in the
selected mode. Check the selected mode.
42-9
Error at positioning start
Check the speed and acceleration parameters. Please contact the Technical
Support team.
Group 43: HW limit switches
43-0
Limit switch: negative setpo
-
int inhibited
The drive has left the intended range of movement.
Technical defect of the system?Check the limit switches.
43-1
Limit switch: positive setpo
-
int inhibited
43-2
Limit switch: positioning
suppressed