57
item Controller BL 1-04 /C
― Product manual
Pin assignment: motor with HIPERFACE DSL
®
1
2
3
4
5
6
7
8
9
back panel of
control cabinet
WEIDMÜLLER
BLF 5.08HC/09/180 SN BK BX
U
V
W
PE
MT +
MT - / DSL -
BR +
BR -
DSL +
connector housing
motor housing
Pin assignment: motor with Hiperface DSL
®
Figure 23: Pin assignment: motor connector (HIPERFACE DSL
®
) [X6]
Pin
Name
Specification
1
U
Motor phase U
2
V
Motor phase V
3
W
Motor phase W
4
PE
Protective earth conductor of the motor
5
MT+
6
MT-/ DSL-
HIPERFACE DSL -
7
DSL+
HIPERFACE DSL +
8
BR+
Holding brake +
9
BR-
Holding brake -
Cable type and configuration [X6]
The cable names that are stated refer to cables made by Lapp. However, it is also possible to use comparable cables from
other manufacturers, for example Lütze or Helukabel.
LAPP KABEL ÖLFLEX SERVO 719 CY; 4 G 1,5 + 2 x (2 x 0,75);
For fixed installation:
LAPP KABEL ÖLFLEX SERVO FD 796 CP; 4 G 1,5 + 2 x (2 x 0,75)
INFO
Comply with the required minimum cross-section
Always observe the minimum cross-sections for the lines U, V, W and PE according to the above table. Comply also with the
maximum permissible cable capacity as per section 8.3 BL 1-04 /C: Motor connector [X6] on page 35.
Connection notes [X6]
Connect the inner and outer cable shield with the greatest possible surface area to the back panel of the control cabinet by
way of suitable EMC terminals (e.g. icotek LFZ/SKL, SFZ/SKL or PFSZ-MSKL). The unshielded cable end should not be longer
than 80 mm.