Group 65: DeviceNet
65-0
DeviceNet active, but no
module
Deactivate the DeviceNet communication or insert a module.
65-1
Timeout I/O Connection
An I/O message has not been received within the expected time.
Group 66: Modbus
66-0
Modbus: no free TCP/IP
connection
Reduce the number of TCP/IP connections.
Group 67: Modbus
67-0
Modbus: timeout TCP/IP
Check the connection to the master.
67-1
Modbus: timeout Modbus
TCP/IP
Check the connection to the master.
67-2
Modbus: buffer overflow
In the master, reduce the cycle time for the transfer of messages to the servo
drive.
67-3
Modbus: message length
too short
Check the configuration of the master.
67-4
Modbus: message length
too long
Check the configuration of the master.
Group 68: Ethernet/IP
68-0
Ethernet/IP: general error
Replace the module.
Please contact the Technical Support team.
68-1
Ethernet/IP: communication
error
Check the connection to the PLC.
68-2
Ethernet/IP: connection
closed
Re-establish the connection.
68-3
Ethernet/IP: connection
timeout
Check the wiring.
68-4
Ethernet/IP: duplicate IP
address
Use an IP address only once on an Ethernet/IP network.
Group 69: Ethernet/IP
69-0
Ethernet/IP: general error
No measures required.
69-1
Ethernet/IP: invalid IP
configuration
Check the IP configuration.
69-2
Ethernet/IP: no technology
module
Insert an Ethernet/IP module into TECH2 or deactivate Ethernet/IP.
69-3
Ethernet/IP: unequal modu
-
le version
Update the firmware of the servo drive.