item Controller BL 1-04 /C
― Product manual
102
59-4
FSM: error management:
too many errors
Cause:
Too many errors have occurred simultaneously. Measure:
▪ Clarify: What is the status of the inserted safety module - does it contain a
valid parameter set?
▪ Read out and analyse the permanent event memory of the servo drive via the
parameterisation program.
▪ Eliminate causes of error step by step.
▪ Install safety module with "delivery status” and perform commissioning of
servo drive.
▪ If this is not available: Set factory settings in the safety module, then copy
data from the servo drive and perform complete validation.
▪ Check whether the error occurs again.
59-7
FSM: flash checksum error
Cause:
• Voltage interruption / power off while parameters were being saved.
• Flash memory in safety module corrupted (e.g. by extreme malfunctions).
Measure:
Check whether the error recurs after a reset. If it does: parameterise the module
again and validate the parameter set again. If error persists: safety module
defective, replace.
59-8
FSM: internal monitoring,
processor 1 - 2
Cause:
• Serious internal error in the safety module: Error detected while dynamising
internal signals
• Disrupted programme sequence, stack error or OP code test failed, proces
-
sor exception /interrupt.
Measure:
Check whether the error recurs after a reset. If it does:
Safety module defective, replace.
59-9
FSM: other unexpected error
Cause:
Triggering of internal programme sequence monitoring.
Measure:
▪ Check the firmware version of the servo drive and the version of the safety
module – update available?
▪ Safety module defective, replace.
Group 60: Ethernet
60-0
Ethernet user-specific (1)
Please contact the Technical Support team.
Group 61: Ethernet
61-0
Ethernet user-specific (2)
Please contact the Technical Support team.