71
item Controller BL 1-04 /C
― Product manual
Cable type and configuration [X3]
Characteristic
Value
Max. cable length, unshielded
30 m
Max. cable length, shielded
> 30 m
Shielding
In the case of wiring outside the control cabinet and with cable lengths > 30 m,
the shield must be led into the control cabinet.
Cable cross-section (flexible conductors, wire end
sleeve with insulating collar), one conductor
0,25 mm²… 0,5 mm²
Minimum wiring for commissioning [X3]
DANGER
Danger to life due to bypassed safety functions
Safety functions must never be bypassed.
For the commissioning of the system without any safety systems, STOA and STOB can be connected to the 24 V supply and
GNDA and GNDB can be connected to GND in a fixed manner.
Perform the minimum wiring of the inputs STOA/STOB and GNDA/GNDB for the commissioning process in such a way that it
must be removed when the final safety wiring is performed.
10 Maintenance, cleaning, repair and disposal
The following requirements must be fulfilled for the maintenance, cleaning, repair and disposal of the servo drive:
Maintenance
Servo drives of the BL 1-04 /C device series are maintenance-free.
Cleaning
NOTICE
Damage to the servo drive due to improper cleaning
To remove surface soiling, e.g. residues of adhesive labels, the servo drive can be cleaned carefully on the outside with suita
-
ble tools.
It must be absolutely ensured that liquids of any kind cannot penetrate the servo drive. Seals may be destroyed which, in turn,
would to lead to short circuits.
Use the servo drive in a clean environment. Soiling due to dust, oil, oil vapour, grease, fibres or similar inside the device will
compromise the insulation with regard to the high- voltage part. Stop using the device immediately if this is the case.
Repair
Opening the device is not permissible and will render the warranty null and void. Only the manufacturer is authorised to per
-
form repairs. Please contact your sales partner.