Goodrive350 IP55 High-ingress Protection Series VFD
Basic Operation Instructions
-98-
Function
code
Name
Description
Default
value
P10.24
Multi-step speed 11
-300.0
–300.0%
0.0%
P10.25
Running time of 11
th
step
0.0
–6553.5s (min)
0.0s
P10.26
Multi-step speed 12
-300.0
–300.0%
0.0%
P10.27
Running time of 12
th
step
0.0
–6553.5s (min)
0.0s
P10.28
Multi-step speed 13
-300.0
–300.0%
0.0%
P10.29
Running time of 13
th
step
0.0
–6553.5s (min)
0.0s
P10.30
Multi-step speed 14
-300.0
–300.0%
0.0%
P10.31
Running time of 14
th
step
0.0
–6553.5s (min)
0.0s
P10.32
Multi-step speed 15
-300.0
–300.0%
0.0%
P10.33
Running time of 15
th
step
0.0
–6553.5s (min)
0.0s
P10.36
PLC restart mode
0: Restart from the first section
1: Continue running at the frequency when
interruption occurred
0
P10.34
Acceleration/deceleration
time of 0
–7 stage of simple
PLC
0x0000
–0XFFFF
0x0000
P10.35
Acceleration/deceleration
time of 8
–15 stage of simple
PLC
0x0000
–0XFFFF
0x0000
P17.00
Set frequency
0.00Hz
–P00.03 (max. output frequency)
0.00Hz
P17.27
Acutal stage of simple PLC
Displays the present stage of the simple
PLC function.
0
5.5.14 Multi-step speed running
Set the parameters used in multi-step speed running. the GD350 IP55 series VFD can set
16-step speeds, which are selectable by multi-step speed terminals 1
–4, corresponding to
multi-step speed 0 to multi-step speed 15.