Intel
®
Server System SR2612UR Service Guide
63
Removing and Installing the Power Distribution Module
Removing the Power Distribution Module
To remove the server board, follow these steps:
1. Power down the enclosure and remove the power cord(s).
2. Remove the top cover from the enclosure by loosening the captive screw with a
Phillips screwdriver on the right-rear of the enclosure.
3. Slide the top cover back and lift it from the enclosure.
4. Remove the processor air duct.
5. Remove the PCI riser assembly.
6. Disconnect power cables, P1, P2, P3 and Front Panel logic cable, from
Motherboard as shown below.
Figure 65. Disconnect the power cables