54
Intel
®
Server System SR2612UR Service Guide
Installing and Removing the RAID Battery Backup Unit
Installing the RAID Battery Backup Unit (BBU)
Warning: Observe ESD precautions when servicing this unit. At a minimum utilize an ESD
grounded wrist strap when handling electrical components. Where possible utilize a
grounded ESD mat to place drives and components on.
To install the RAID battery backup unit, follow these steps:
1. Power down the enclosure and remove the power cord(s).
2. Remove all disk drives. Note their slot location in the enclosure.
3. Remove the top cover from the enclosure by loosening the captive screw with a
Phillips screwdriver on the right-rear of the enclosure.
4. Slide the top cover back and lift it from the enclosure.
5. Locate the battery mounting plate in the enclosure as shown below
Figure 51. Locate the battery