Intel
®
Server System SR2612UR Service Guide
21
Configuration Jumpers
Jumper Name
Jumper Purpose
A.
Serial Port Configuration
(J9A1)
If pins 1-2 are jumpered, the DCD to DTR mode is enabled. These
pins should be jumpered on 3-4 to operate in the DSR to DTR
(default) mode.
B.
BMC Force Update
(J1H2)
If pins 2-3 are jumpered, the Integrated BMC Force Update Mode is
enabled. These pins should be jumpered on 1-2 for normal system
operation.
C.
BIOS Default (J1E7)
If pins 2-3 are jumpered, the BIOS settings are cleared on the next
reset. These pins should be jumpered on 1-2 for normal operation.
D.
Password Clear (J1E8)
If pins 2-3 are jumpered, administrator and user passwords are
cleared within five to ten seconds after the system is powered on.
These pins should be jumpered on 1-2 for normal system
operation.
AF002832
J1D4
BIOS Recover
2
3
Normal
Recover
J1E8
Password Clear
2
3
Protect
Clear
J1E7
BIOS Default
2
3
Normal
Set
Default
J1H2
BMC Force Update
2
3
Disable
Enable
J9A1
Serial Port
Configuration
3
4
2
DCD to DTR
DSR to DTR
(factory default)
E
D
C
B
A
Summary of Contents for SR2612UR - Server System - 0 MB RAM
Page 14: ...xiv Intel Server System SR2612UR Service Guide ...
Page 98: ...84 Intel Server System SR2612UR Service Guide ...
Page 102: ...88 Intel Server System SR2612UR Service Guide ...
Page 104: ...90 Intel Server System SR2612UR Service Guide ...
Page 136: ...122 Intel Server System SR2612UR Service Guide ...
Page 158: ...144 Intel Server System SR2612UR Service Guide ...
Page 159: ...Intel Server System SR2612UR Service Guide 145 ...
Page 160: ...146 Intel Server System SR2612UR Service Guide ...
Page 161: ...Intel Server System SR2612UR Service Guide 147 ...
Page 162: ...148 Intel Server System SR2612UR Service Guide ...