Intel
®
Server System SR2612UR Service Guide
47
To replace or add memory to the Intel
®
Server System SR2612UR, complete the
following steps.
1. Ensure that the AC power cord(s) are disconnected from the enclosure.
2. Remove the top cover from the enclosure by loosening the captive screw with a
Phillips screwdriver on the right-rear of the enclosure.
3. Slide the top cover back and lift it from the enclosure.
4. Carefully remove the system air duct over the CPU server board.
5. Referencing the following Server Board Configuration Diagram, memory DIMMs
must be installed / filled in the following order:
—
Slot A1, Slot B1, Slot C1 (CPU 1)
—
Slot D1, Slot E1, Slot F1 (CPU 2)
Once the above slots are full, then:
—
Slot A2, Slot B2, Slot C2 (CPU1)
—
Slot D2, Slot E2, Slot F2 (CPU2)
Figure 40. Memory Slots on the Server Board
Note: You can populate memory in any order only if the CPU server board is running in
Channel Independent Mode. Please reference the CPU server board functional
specification if the enclosure will be running in Channel Independent Mode. Also refer to
the specification if the server board will be running in either Channel Sparing or Channel
Mirroring Mode as there are specific memory installation configurations required.
6. To install the DIMM, open the release levers on each side of the memory socket and
press down on the DIMM until the release levers snap closed.
Summary of Contents for SR2612UR - Server System - 0 MB RAM
Page 14: ...xiv Intel Server System SR2612UR Service Guide ...
Page 98: ...84 Intel Server System SR2612UR Service Guide ...
Page 102: ...88 Intel Server System SR2612UR Service Guide ...
Page 104: ...90 Intel Server System SR2612UR Service Guide ...
Page 136: ...122 Intel Server System SR2612UR Service Guide ...
Page 158: ...144 Intel Server System SR2612UR Service Guide ...
Page 159: ...Intel Server System SR2612UR Service Guide 145 ...
Page 160: ...146 Intel Server System SR2612UR Service Guide ...
Page 161: ...Intel Server System SR2612UR Service Guide 147 ...
Page 162: ...148 Intel Server System SR2612UR Service Guide ...