Intel
®
Server System SR2612UR Service Guide
51
14. Reinstall the power cord(s).
Power Supply Replacement
Complete the following steps to remove and install a power supply in the Intel
®
Server
System SR2612UR.
1. Ensure the AC power cord(s) are disconnected from the enclosure.
2. Remove the top cover from the enclosure by loosening the captive screw on the
right-rear of the enclosure with a Phillips screwdriver.
3. Slide the top cover back and lift it from the enclosure.
4. Remove the power supply by pushing in and holding the green latch in the
directions shown in the following figure.
Figure 45. Removing the Power Supply
5. Using the handle, carefully slide the power supply out of the enclosure chassis.
6. Reinstall a new power supply by inserting it into the chassis enclosure until it clicks
into place.
7. Reinstall the top cover and tighten the captive screw.
8. Reinstall the power cord(s).
Replacing the Backplane Board
The following sections describe how to replace the backplane board.
Summary of Contents for SR2612UR - Server System - 0 MB RAM
Page 14: ...xiv Intel Server System SR2612UR Service Guide ...
Page 98: ...84 Intel Server System SR2612UR Service Guide ...
Page 102: ...88 Intel Server System SR2612UR Service Guide ...
Page 104: ...90 Intel Server System SR2612UR Service Guide ...
Page 136: ...122 Intel Server System SR2612UR Service Guide ...
Page 158: ...144 Intel Server System SR2612UR Service Guide ...
Page 159: ...Intel Server System SR2612UR Service Guide 145 ...
Page 160: ...146 Intel Server System SR2612UR Service Guide ...
Page 161: ...Intel Server System SR2612UR Service Guide 147 ...
Page 162: ...148 Intel Server System SR2612UR Service Guide ...