The external temperature sensor input has the following electrical specifications.
Specification
Value
Type of input
Single ended
ESD protection
1000 V (Human Body Model)
300 V (Machine Model)
8.2.12 Motor wiring recommendations
Wire section
The minimum wire section is determined by the motor current. It is preferred to use wide section stranded wires to reduce impedance, power losses and ease the
assembly. Insulator size should not exceed 5 mm (connector pitch). Following table indicates recommended section:
Connection
Minimum wire size
Maximum wire size
Stranded wire (preferred)
1.5 mm
2
4 mm
2
Solid wire
1.5 mm
2
4 mm
2
Wire length
The distance between the Jupiter Servo Drive and the motor
. Short cables are preferred since they reduce power losses as well
should be minimized when possible
as electromagnetic emissions and immunity.
Avoid running motor wires in parallel with other wires for long distances, especially feedback and signal wires.