Installation Guide
INGENIA MOTION CONTROL
Confidential and proprietary information.
Unauthorized Copies Prohibited.
Page
of
37
307
Protections
User configurable:
Bus over-voltage
Bus under-voltage
Over temperature
Under temperature
Over current
Overload (I t)
2
Short-circuit protections:
Phase-DC bus
Phase-phase
Mechanical limits for homing functions
Hall sequence/combination error
ESD & EMI protections: ESD protections are available in all inputs, outputs and communications. All inputs, outputs,
feedbacks include noise filters.
Inverse polarity supply protection (bidirectional)
High power transient voltage suppressor for short braking: A TVS diode (600 W peak) protects the circuitry from the voltage
transients events
Encoder broken wire (for differential quadrature encoders only).
Ambient air temperature
-40 ºC to +50 ºC full current (operating)
+50 ºC to +100 ºC current derating (operating)
-50 ºC to -40ºC and 100ºC to +125 ºC (non-operating)
Maximum humidity
5% - 85% (non-condensing)