EonStor S12E-R1132-4/G1133-2 Installation and Hardware Reference Manual
․
Host link cables
: For the compliance with listed emission
standard, RJ-45 STP cables should be applied. Infortrend
provides certified cables as an optional accessory. One 3-
meter STP Ethernet cable is available as an accessory
option.
․
COM2
serial cable for connecting UPS device.
․
One (1) or two (2) Ethernet cables to the 10/100BasetT
management port
.
Please see
Section 4.2
for sample topologies and configuration
options. As to the accessory info, please visit Infortrend
webpage
www.infortrend.com
.
5.
Memory modules:
If you wish to replace the pre-installed DDR
RAM DIMM module, please refer to
Section 5.3
.
6.
BBU:
If you wish to install a BBU to S12E-G1133-2, the BBU
must be purchased separately and installed prior to powering on
the subsystem. (See
Section 2.9
)
7. Mixing SAS and SATA drives in the same enclosure is allowed.
However, please DO NOT mix SAS and SATA-II drives in the
same drive column.
8. DO NOT place a column of SATA-II disk drives between two
columns of SAS disk drives. With a higher rotation speed, the
SAS disk drives on the flank of SATA-II disk drives will eventually
cause a stability issue. Please see
Figure 2-1
for the supported
and unsupported configuration of mixing columns of SATA and
SAS drives.
2-2