10. Registers > IDT Specific Event Notification Control Registers
CPS-1848 User Manual
283
June 2, 2014
Formal Status
This document is confidential and is subject to an NDA.
Integrated Device Technology
10.10.3 Configuration Block Error Capture Enable Register
30
I2C_ACK_ERR
0 = No error
1 = An acknowledgement was expected but not received. This
error can occur in Master or Slave mode. If the error occurs in
Master mode, the data transfer will be terminated and the error
will be captured.
RW
0
31
I2C_LENGTH_ERR
0 = No error
1 = I2C transmission has an invalid data payload length (read or
write transaction)
RW
0
Register Name: CFG_ERR_CAPT_EN
Reset Value: 0x0000_0000
Register Offset: 0x020008
Bits
0
1
2
3
4
5
6
7
00:07
Reserved
08:15
Reserved
16:23
Reserved
24:31
Reserved
BAD_MCA
ST_EN
BAD_RTE_
EN
RTE_FORC
E_EN
BAD_PORT
_EN
BAD_MAS
K_EN
Bits
Name
Description
Type
Reset
Value
0:26
Reserved
Reserved
RO
0
27
BAD_MCAST_EN 0 = Disable
1 = Enable multicast translation error capture
RW
0
28
BAD_RTE_EN
0 = Disable
1 = Enable route table configuration error capture
RW
0
29
RTE_FORCE_EN 0 = Disable
1 = Enable force local configuration error capture
RW
0
30
BAD_PORT_EN
0 = Disable
1 = Enable port configuration error capture
RW
0
31
BAD_MASK_EN
0 = Disable
1 = Enable multicast mask configuration error capture
RW
0
(Continued)
Bits
Name
Description
Type
Reset
Value