6. Event Management > Event Notification
CPS-1848 User Manual
141
June 2, 2014
Formal Status
This document is confidential and is subject to an NDA.
Integrated Device Technology
Protocol error
Port {0..17} Error Report Enable
Register
.PRTCL_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
.PRTCL_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.PRTCL_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Delineation error
Port {0..17} Error Report Enable
Register
.DELIN_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.DELIN_ERR_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Unsolicited acknowledgement
control symbol
Port {0..17} Error Report Enable
Register
.CS_ACK_ILL_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
.CS_ACK_ILL_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.CS_ACK_ILL_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Link timeout
Port {0..17} Error Report Enable
Register
.LINK_TIMEOUT_EN =
1 and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Error Report Enable
Register
.LINK_TIMEOUT_EN =
1 and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Error Report Enable
Register
.LINK_TIMEOUT_EN =
1 and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received a packet when an error
rate threshold event has
occurred and drop packet mode
is enabled
Port {0..17} Implementation
Specific Error Report Enable
Register
.ERR_RATE_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.ERR_RATE_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.ERR_RATE_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
A packet was dropped due to a
TTL event
Port {0..17} Implementation
Specific Error Report Enable
Register
. TTL_EVENT_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
. TTL_EVENT_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
. TTL_EVENT_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
A transmitted packet was
dropped via CRC error
retransmit limit
Port {0..17} Implementation
Specific Error Report Enable
Register
.CRC_EVENT_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.CRC_EVENT_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.CRC_EVENT_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Table 53: Physical Layer Event Notification Control (Continued)
Event
Standard Port-Write Reporting
Interrupt Reporting
Error Log Reporting