6. Event Management > Event Notification
CPS-1848 User Manual
143
June 2, 2014
Formal Status
This document is confidential and is subject to an NDA.
Integrated Device Technology
Received a packet that
references a port configuration in
port lockout and is dropped
Port {0..17} Implementation
Specific Error Report Enable
Register
.RTE_ISSUE_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.RTE_ISSUE_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.RTE_ISSUE_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received a packet that
references a port in the fatal
error state and is dropped
Port {0..17} Implementation
Specific Error Report Enable
Register
.RTE_ISSUE_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.RTE_ISSUE_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.RTE_ISSUE_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Set outstanding ackID invalid
Port {0..17} Implementation
Specific Error Report Enable
Register
.SET_ACKID_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.SET_ACKID_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Discarded a non-maintenance
packet to be transmitted
Port {0..17} Implementation
Specific Error Report Enable
Register
.TX_DROP_EN = 1 and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.TX_DROP_EN = 1 and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
RX retry count triggered
congestion
Port {0..17} Implementation
Specific Error Report Enable
Register
.MANY_RETRY_EN = 1
and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.MANY_RETRY_EN = 1
and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.MANY_RETRY_EN = 1
and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Discarded a received
non-maintenance packet
Note: The packet is not accepted
by the receiver, but the
transmitter retains the packet.
The packet remains in the
system.
Port {0..17} Implementation
Specific Error Report Enable
Register
.RX_DROP_EN = 1 and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.RX_DROP_EN = 1 and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Received a packet that has an
invalid TT
Port {0..17} Implementation
Specific Error Report Enable
Register
.BAD_TT_EN = 1 and
Port {0..17} Operations
Register
.PORT_PW_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.BAD_TT_EN = 1 and
Port {0..17} Operations
Register
.PORT_INT_EN = 1
Port {0..17} Implementation
Specific Error Report Enable
Register
.BAD_TT_EN = 1 and
Port {0..17} Operations
Register
.PORT_LOG_EN = 1
Table 53: Physical Layer Event Notification Control (Continued)
Event
Standard Port-Write Reporting
Interrupt Reporting
Error Log Reporting