![IDEC FS1A-C11S User Manual Download Page 67](http://html.mh-extra.com/html/idec/fs1a-c11s/fs1a-c11s_user-manual_617376067.webp)
LOGIC
5-19
C
h
a
p
te
r 5
Logic 11A: The logic for apparatus with openings
Overview (Logic 11A)
This logic is for using safety devices with dual channel solid state outputs, such as safety light
curtains, for safety protective measures of production machinery and robots. Safety outputs perform
as dual channel outputs.
This logic enables the connection of 2 dual channel direct opening inputs and 4 dual channel safety
inputs.
Safety input 1
Safety input 6
Safety input 2
Safety input 3
Safety output 1
or
Safety output 2
Safety input 4
Safety input 5
System runs
Safety
output 1
Safety
output 2
Logic 11A
Emergency
stop switch
Safety light
curtain
(PNP type
)
Safety switch
Operation example (Logic 11A)
System stops
Beams
blocked!
Safety input 1
Safety input 5
Safety input 6
Safety input 4
Safety input 3
Safety input 2
Safety output 1
or
Safety output 2
Press!
Summary of Contents for FS1A-C11S
Page 1: ...FS9Z B1218 FS1A C11S Safety Controller SafetyOne User s manual ...
Page 2: ......
Page 10: ......
Page 16: ...PRODUCT SPECIFICATIONS 2 4 Dimensions Detail of locking ring Locking ring ...
Page 38: ...INSTALLATION AND WIRING 3 8 ...
Page 48: ...BASIC OPERATIONS 4 10 ...
Page 78: ...LOGIC 5 30 ...
Page 90: ...LOGIC 5 42 ...
Page 102: ...LOGIC 5 54 ...
Page 116: ...LOGIC 5 68 ...
Page 154: ...LOGIC 5 106 ...
Page 231: ...LOGIC 5 183 Chapter 5 ...
Page 307: ...LOGIC 5 259 Chapter 5 ...
Page 319: ...LOGIC 5 271 Chapter 5 ...
Page 331: ...LOGIC 5 283 Chapter 5 ...
Page 386: ...LOGIC 5 338 ...