![IDEC FS1A-C11S User Manual Download Page 297](http://html.mh-extra.com/html/idec/fs1a-c11s/fs1a-c11s_user-manual_617376297.webp)
LOGIC
5-249
C
h
a
p
te
r 5
Intended inputs
(Terminal names)
Function
Safety input 5
(X10, X11)
Function name
Dual channel safety input
Symbol
Dual Channel Safety
Description of operation
This function diagnoses the status of
connected safety devices. This function
diagnoses the time interval of status
transition between each input of
duplicated inputs (0.1s). The function
does not use drive terminals (T10 and
T11).
Detail information
Logic functions (5-317)
Warning
For connected control devices, refer to “SAFETY PRECAUTIONS”.
Safety check signals (pulses signals) are sent from the drive terminals (T0, T2 to T7) to diagnose
connected safety devices and input circuits. Safety check signals can not be used as a power supply
for connected devices.
Note. Solid state outputs, such as safety light curtains, can not be connected to safety input1 through
safety input 4.
Note. Use safety input 1 through safety input 4, as specified combinations, such as receive terminal
(Xn) and drive terminal (Tn). If the combinations are incorrect, SafetyOne does not work
correctly.
Note. When SafetyOne is in Run state or Protection state, input states are monitored in all safety
inputs. For example, if input monitor error is detected in safety input 2 although AUTO mode is
selected, SafetyOne detects error and transits to Protection state.
Note. If there are unused safety inputs in safety input 2 through safety input 4, connect the unused
receive terminals (Xn) to the corresponding drive terminals (Tn). If they are not connected, the
SafetyOne does not turn ON the safety outputs.
Note. If safety input 5 is not used, connect the receive terminals (X10 and X11) to a 24V DC power
supply (V+). If they are not connected, the SafetyOne does not turn ON the safety outputs.
Summary of Contents for FS1A-C11S
Page 1: ...FS9Z B1218 FS1A C11S Safety Controller SafetyOne User s manual ...
Page 2: ......
Page 10: ......
Page 16: ...PRODUCT SPECIFICATIONS 2 4 Dimensions Detail of locking ring Locking ring ...
Page 38: ...INSTALLATION AND WIRING 3 8 ...
Page 48: ...BASIC OPERATIONS 4 10 ...
Page 78: ...LOGIC 5 30 ...
Page 90: ...LOGIC 5 42 ...
Page 102: ...LOGIC 5 54 ...
Page 116: ...LOGIC 5 68 ...
Page 154: ...LOGIC 5 106 ...
Page 231: ...LOGIC 5 183 Chapter 5 ...
Page 307: ...LOGIC 5 259 Chapter 5 ...
Page 319: ...LOGIC 5 271 Chapter 5 ...
Page 331: ...LOGIC 5 283 Chapter 5 ...
Page 386: ...LOGIC 5 338 ...