![IDEC FS1A-C11S User Manual Download Page 54](http://html.mh-extra.com/html/idec/fs1a-c11s/fs1a-c11s_user-manual_617376054.webp)
LOGIC
5-6
Using IDEC non-contact interlock switches HS7A series
S1, 2 : HS7A-DMC59** (1NO+1NC Contact, with LED / without LED) or
HS7A-DMP50** (1NO+2NC Contact, with LED / without LED)
S3, 4, 5 : HS7A-DMC790* (2NO Contact, without LED) or
HS7A-DMP700* (2NO+1NC Contact, without LED)
S 1
X n + 1
X n
T n + 1
T n
W H
B N +
B K
B U
S 3
X p
X p + 1
T p
T p + 1
S 1
S 3
S 2
S 4
X m
X m + 1
T m
T m + 1
S 5
X n + 1
X n
T n + 1
T n
X m
X m + 1
T m
T m + 1
D ual C hannel
D
ependent
D ual C hannel
D irect O pening
D ual C hannel
N O /N C
W H
B N +
B K
B U
W H
B N +
B K
B U
W H
B N +
B K
B U
W H
B N +
B K
B U
W H
B N +
B K
B U
W H
B N +
B K
B U
Note 1) Above illustration shows contact when actuator is present in the sensing area.
Note 2) The HS7A-DMC59** or the HS7A-DMP50** can be connected to the dual channel NO/NC inputs.
Note 3) The HS7A-DMC790* or the HS7A-DMP700* can be connected to the dual channel direct opening inputs
or dual channel dependent inputs.
Note 4) In the case of using HS7A-DMC790* or HS7A-DMP700*, safety performance depends on result of risk
assessment for whole of the safety configuration.
Common connection of several non-contact interlock
switches
note6)
Summary of Contents for FS1A-C11S
Page 1: ...FS9Z B1218 FS1A C11S Safety Controller SafetyOne User s manual ...
Page 2: ......
Page 10: ......
Page 16: ...PRODUCT SPECIFICATIONS 2 4 Dimensions Detail of locking ring Locking ring ...
Page 38: ...INSTALLATION AND WIRING 3 8 ...
Page 48: ...BASIC OPERATIONS 4 10 ...
Page 78: ...LOGIC 5 30 ...
Page 90: ...LOGIC 5 42 ...
Page 102: ...LOGIC 5 54 ...
Page 116: ...LOGIC 5 68 ...
Page 154: ...LOGIC 5 106 ...
Page 231: ...LOGIC 5 183 Chapter 5 ...
Page 307: ...LOGIC 5 259 Chapter 5 ...
Page 319: ...LOGIC 5 271 Chapter 5 ...
Page 331: ...LOGIC 5 283 Chapter 5 ...
Page 386: ...LOGIC 5 338 ...