![IDEC FS1A-C11S User Manual Download Page 230](http://html.mh-extra.com/html/idec/fs1a-c11s/fs1a-c11s_user-manual_617376230.webp)
LOGIC
5-182
Example: Auto mode
Monitor output for
Safety output 1: Y12
State monitor output 3:
Y16
Safety input 1: X0
(Mode select input:
Teach mode)
Safety input 3:
X4
Monitor output for
safety input 3: Y6
Monitor output for
safety input 1: Y4
Monitor output for
safety input 5: Y10
Safety input 1: X1
(Mode select input:
Auto mode)
Safety input 5:
X10, X11
Start input 2: X17
(Control)
Safety input 3:
X5
note 1)
Max. 0.1s
Safety output 1:
Y0, Y1
Safety output 2:
Y2, Y3
Monitor output for
Safety output 2: Y13
Solenoid output 1:
Y17
Solenoid output 2:
Y20
Monitor output for
safety input 6: Y11
Safety input 6:
X12, X13
Safety input 2:
X2, X3
Monitor output for
safety input 2: Y5
OFF delay time
0.1s to 5s
OFF delay time
OFF delay time
note 1)
Start input 1: X16
(Manual)
Safety
output
1, 2
ON
Safety
output
1, 2
ON
Safety
output 2
ON
Switch to
Teach
mode
OFF delay time
Safety
output
1, 2
ON
Max. 0.1s
Min. 0.1s
(Safety input 4 is ON in this chart.)
Summary of Contents for FS1A-C11S
Page 1: ...FS9Z B1218 FS1A C11S Safety Controller SafetyOne User s manual ...
Page 2: ......
Page 10: ......
Page 16: ...PRODUCT SPECIFICATIONS 2 4 Dimensions Detail of locking ring Locking ring ...
Page 38: ...INSTALLATION AND WIRING 3 8 ...
Page 48: ...BASIC OPERATIONS 4 10 ...
Page 78: ...LOGIC 5 30 ...
Page 90: ...LOGIC 5 42 ...
Page 102: ...LOGIC 5 54 ...
Page 116: ...LOGIC 5 68 ...
Page 154: ...LOGIC 5 106 ...
Page 231: ...LOGIC 5 183 Chapter 5 ...
Page 307: ...LOGIC 5 259 Chapter 5 ...
Page 319: ...LOGIC 5 271 Chapter 5 ...
Page 331: ...LOGIC 5 283 Chapter 5 ...
Page 386: ...LOGIC 5 338 ...