![IDEC FS1A-C11S User Manual Download Page 242](http://html.mh-extra.com/html/idec/fs1a-c11s/fs1a-c11s_user-manual_617376242.webp)
LOGIC
5-194
When using the start switch S7
(
Manual start
)
When not using the start switch S7
(
Auto start
)
When connecting multiple emergency stop
switches in series
NOTE:
S
afety performance depends
on the system configuration.
When not using some safety inputs
・
If there are unused safety inputs in S3, S4, or S6,
connect the unused receive terminals
to the corresponding drive terminals. (Refer to (1))
・
If S5 is not used, connect the receive terminal
to 24V DC power supply (V+). (Refer to (2))
X16
X17
24V DC
S
8
X16
X17
24V DC
S7
S
8
X12
T12
X13
T13
X
n
X
n+1
T
n
T
n+1
X
m
X
m+1
T
m
T
m+1
24V DC
(1)
(2)