LOGIC
5-119
C
h
a
p
te
r 5
Example: Control start input (X17) is used.
Safety input 1: X0
Start input 2: X17
(Control)
Monitor output for
safety input 1: Y4
State monitor output 3:
Y16
Solenoid output 1:
Y17
Safety input 1: X1
Max. 6s
Initialization
Safety input 2:
X2, X3
Safety output 1:
Y0, Y1
Monitor output for Safety
output 1: Y12
Safety output 2:
Y2, Y3
Monitor output for Safety
output 2: Y13
Solenoid output 2:
Y20
Monitor output for
safety input 2: Y5
Safety input 3:
X4, X5
Monitor output for
safety input 3: Y6
note 1)
note 1)
0.1s to 5s
Max. 0.1s
Power
ON
Safety
output
ON
OFF delay time
OFF delay time
Safety
output
ON
Safety
output
ON
(Safety input 4, 5 and 6 are all ON in this chart.)