Warning
Do not connect devices having input and output specifications that do not satisfy the
requirements of the SafetyOne.
Refer to the following for information on the requirements of connected devices.
Connected Control Device
Requirements
Emergency stop switch
Device equipped with a direct opening action mechanism conforming to
IEC/EN60947-5-5 or indicated in IEC/EN60947-5-1
Interlock switch,
limit switch
Device equipped with a direct opening action mechanism indicated in
IEC/EN60947-5-1
Interlock switch with lock
Spring lock interlock switch with solenoid
Mode select switch
Device conforming to regulations of the country where used and required
categories (for example, switch conforming to IEC/EN60947-1)
Enabling switch
Device conforming to IEC/EN60947-5-8 (or IEC/EN60947-5-1)
Solid state output device
Device conforming to regulations of the country where used (for example,
safety light curtain conforming to IEC/EN61496-1)
PNP output (See Note 1)
Non-contact interlock switch IDEC HS7A series, IDEC HS3A serise
Safety relay
Relay equipped with forced guide mechanism or conforming to EN50205
Contactor
(electromagnetic switch)
Contactor equipped with forced guide mechanism
Other control devices
Use start switches and other devices that conform to the regulations of the
country where used.
Muting sensor
Device conforming to IEC/EN60947-5-2 as shown below
-3 wire transmission (dark on) photoelectric switch which has a PNP open
collector output.
-3 wire (normal open) proximity switch which has a PNP open collector
output.
Muting lamp
Incandescent bulb indicator light conforming to IEC/EN60947-1 or
IEC/EN60947-5-1
Note 2: It is not possible to detect a disconnection of the muting lamp when
using an LED indicator light.
Input device for two-hand
control
Device witch the structure conforming to ISO13851, and consists of
momentary switches conforming to IEC/EN 60947-5-1 with NO/NC contacts.
Make sure that the end-
user thoroughly understands the contents of this user’s manual.
Note 1. SafetyOne reads input data at regular intervals. Use a solid state output device that sends
output signals of the waveforms shown below. Otherwise the SafetyOne cannot process the input
signal correctly.
Applicable solid state
output device
Pulse output off cycle of 40ms or
more and an off time of 1ms or less.
Pulse output off time of 0.5ms or
less.
(Waveform of solid sate
output)
The device may not be usable even if the above specifications are satisfied. Be sure to
thoroughly confirm operations using the actual device.
Off cycle: 40ms or more
Off time:
1ms or less
Off time: 0.5ms or less
Summary of Contents for FS1A-C11S
Page 1: ...FS9Z B1218 FS1A C11S Safety Controller SafetyOne User s manual ...
Page 2: ......
Page 10: ......
Page 16: ...PRODUCT SPECIFICATIONS 2 4 Dimensions Detail of locking ring Locking ring ...
Page 38: ...INSTALLATION AND WIRING 3 8 ...
Page 48: ...BASIC OPERATIONS 4 10 ...
Page 78: ...LOGIC 5 30 ...
Page 90: ...LOGIC 5 42 ...
Page 102: ...LOGIC 5 54 ...
Page 116: ...LOGIC 5 68 ...
Page 154: ...LOGIC 5 106 ...
Page 231: ...LOGIC 5 183 Chapter 5 ...
Page 307: ...LOGIC 5 259 Chapter 5 ...
Page 319: ...LOGIC 5 271 Chapter 5 ...
Page 331: ...LOGIC 5 283 Chapter 5 ...
Page 386: ...LOGIC 5 338 ...