LOGIC
5-137
C
h
a
p
te
r 5
●Safety outputs: Y0 to Y3
Safety outputs are used to output safety information processed by SafetyOne.
Intended outputs
(Terminal names)
Function
Safety output 1
(Y0, Y1)
Safety output 2
(Y2, Y3)
Function name
Safety output with timer
Symbol
Hold
EDM
OSSD
with
Off delay
Description of operation
This function is a safety output to output safety
information processed by SafetyOne. The
output is turned OFF after the preset time of the
OFF-delay timer (OFF-delay output).
Detail information
Logic functions (5-335)
Note. When the SafetyOne changes to Protection state due to input monitor error, all safety outputs
(safety output 1 and safety output 2) are turned OFF after the preset OFF-delay time.
Note. When the SafetyOne changes to Stop state due to circuit failure or other errors, all safety
outputs (safety output 1 and safety output 2) are turned OFF, immediately.
Note. Set time of safety output with timer is active independent of the selected mode.
●Safety input monitor outputs: Y4 to Y11
Safety input monitor outputs are used to output the status of safety inputs in SafetyOne.
Intended outputs
(Terminal names)
Target safety inputs
(Terminal names)
Description of operation
Safety input 1 monitor output
(Y4)
Safety input 1
(X0-T0: TEACH)
When TEACH mode (X0) is selected,
the monitor output is ON. When
TEACH mode is not selected, the
monitor output is OFF.
Safety input 2 monitor output
(Y5)
Safety input 2
(X2-T2, X3-T3)
When the target safety input is ON,
the monitor output is ON. When the
target safety input is OFF, the monitor
output is OFF.
Safety input 3 monitor output
(Y6)
Safety input 3
(X4-T4, X5-T5)
Safety input 4 monitor output
(Y7)
Safety input 4
(X6-T6, X7-T7)
Safety input 5 monitor output
(Y10)
Safety input 5
(X10, X11)
Safety input 6 monitor output
(Y11)
Safety input 6
(X12-T12, T13-X13)
Note. When the targeted safety input detects an input monitor error, input circuit failure or EMC the
disturbance, corresponding safety input monitor output becomes a pulse output (1Hz). The
monitor output is OFF in other errors, Initial state, or Configuration state.
Summary of Contents for FS1A-C11S
Page 1: ...FS9Z B1218 FS1A C11S Safety Controller SafetyOne User s manual ...
Page 2: ......
Page 10: ......
Page 16: ...PRODUCT SPECIFICATIONS 2 4 Dimensions Detail of locking ring Locking ring ...
Page 38: ...INSTALLATION AND WIRING 3 8 ...
Page 48: ...BASIC OPERATIONS 4 10 ...
Page 78: ...LOGIC 5 30 ...
Page 90: ...LOGIC 5 42 ...
Page 102: ...LOGIC 5 54 ...
Page 116: ...LOGIC 5 68 ...
Page 154: ...LOGIC 5 106 ...
Page 231: ...LOGIC 5 183 Chapter 5 ...
Page 307: ...LOGIC 5 259 Chapter 5 ...
Page 319: ...LOGIC 5 271 Chapter 5 ...
Page 331: ...LOGIC 5 283 Chapter 5 ...
Page 386: ...LOGIC 5 338 ...